Evaluation of Initial Stress Distribution and Displacement Pattern of Craniofacial Structures with 3 Different Rapid Maxillary Expansion Appliance Models: A 3-dimensional Finite Element Analysis
    PDF
    Cite
    Share
    Request
    Original Article
    P: 18-25
    March 2021

    Evaluation of Initial Stress Distribution and Displacement Pattern of Craniofacial Structures with 3 Different Rapid Maxillary Expansion Appliance Models: A 3-dimensional Finite Element Analysis

    Turk J Orthod 2021;34(1):18-25
    1. Specialist in Orthodontics, Private practice, Istanbul, Turkey
    2. Department of Orthodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey
    3. Department of Orthodontics, Faculty of Dentistry, Altinbas University, Istanbul, Turkey
    No information available.
    No information available
    Received Date: 28.04.2020
    Accepted Date: 12.10.2020
    PDF
    Cite
    Share
    Request

    ABSTRACT

    Objective:

    This study aimed to describe the displacement of anatomical structures and the stress distributions caused by the Hyrax, fan-type, and double-hinged expansion screws via the 3-dimensional (3D) finite element method (FEM).

    Methods:

    The 3D FEM was based on the computed tomography data of a 12-year-old patient with a constricted maxilla. The Hyrax model included 1,800,981 tetrahedral elements with 2,758,217 nodes. The fan-type model included 1,787,558 tetrahedral elements with 2,737,358 nodes. The double-hinged model included 1,777,080 tetrahedral elements with 2,722,771 nodes. The von Mises stress distributions after 0.2 mm of expansion and displacement patterns after 5 mm of expansion were evaluated.

    Results:

    The highest stress accumulation was observed in the sutura zygomatico maxillaris area with all 3 appliances. An increase in stress was noted at the pterygomaxillary fissure, the medial and lateral pterygoid process of the sphenoid bone, and the nasal areas. The wedge-shaped skeletal opening was observed with all 3 appliances. In the transverse plane, maximum posterior expansion was achieved with the Hyrax appliance, whereas the maximum anterior expansion was observed with the double-hinged appliance. The maxilla moved inferiorly and anteriorly with all the 3 appliances. The greatest inferior displacement of the maxilla was recorded with the Hyrax appliance, whereas anterior maxillary displacement was the greatest with the double-hinged appliance.

    Conclusion:

    All the appliances showed similar stress distributions. The use of double-hinged screw caused a slight anterior displacement of point A. The fan-type and double-hinged appliances were shown to be more effective on anterior maxillary constriction, whereas the Hyrax appliance might be chosen for resolving maxillary posterior constriction.

    Article is only available in PDF format. Show PDF
    2024 ©️ Galenos Publishing House